No results found for your search
flag_en English
tested system

GU pre-wall frame

With the fully assembled GU pre-wall frame including its system components, we offer you an optimal installation frame for the secure and efficient installation and sealing around your wall opening. This allows door and window elements to be installed flexibly and just as easily as with conventional reveal installation, in any desired installation position in front of the masonry. In addition, our frame system is certified for burglar resistance up to RC3 according to EN 1627-1630, providing you with additional security. The excellent building physics properties enable thermal bridge-free and energy-efficient installation. At the same time, you effortlessly meet all structural requirements as well as the high standards regarding driving rain, wind, sound, and airtightness – regardless of the type of façade.

Construction worker installs GU front mounting frame on a house wall during shell construction

The tested system for pre-wall installation at a glance

  • Effective sound insulation up to 46 dB according to DIN 4109
  • Suitable for fall-proof element fixing according to DIN 18008 and ETB guideline
  • RC3 approval according to EN 1627-1630
  • Fire behaviour: approved according to EN 13501-1, class E and DIN 4102-1, class B1
  • Approved for passive houses: Ψ = 0.01 W (m-K)
  • Thermal bridge-free
  • Thermal conductivity EN 12667:2001 λ = 0.0307 (W/mK)
  • High characteristic load transfer up to 1233 kg/m
  • High UV and weather resistance
  • Large tolerance compensation for installation and building tolerances
  • Window replacement in the façade without damage
  • Installation and sealing according to the recognized rules of technology
system description

The ideal solution for modern façade, window, and door elements

With the GU pre-wall frame, you can securely fasten and reliably seal your façade, window, and door elements. Thanks to its excellent insulation properties, it is perfectly suited for low-energy and passive houses and meets the highest requirements for energy efficiency and airtightness. The flexible pre-wall installation allows for easy integration of various building components, prevents thermal bridges, and is particularly advantageous for energy-efficient building renovations. Its robust construction and tested load-bearing capacity ensure that even heavy windows and doors are securely fixed – all in compliance with all relevant standards, including burglar resistance according to EN 1627-1630. With the GU pre-wall frame, you receive an efficient, durable, and cost-effective solution for your modern window installation.

System components GU front-mounted frame

GU front-mounted frame

  • Material: rigid particle foam free of CFC made of EPS (expanded polystyrene)
  • Easy to process, low bulk density
  • Very high stability and elasticity
  • The air enclosed in the foam beads ensures excellent thermal properties

GU mounting anchor

  • System screw made of electro-galvanized steel with matching polyamide anchor sleeve, which is expanded by screwing the special screw into the plastic anchor
  • Secure fastening for flush-mounted pre-frame installation on the load-bearing masonry with 70 mm edge distance from the drilled hole to the edge of the masonry and a 90 mm contact width of the GU pre-frame to the load-bearing shell

GU mounting anchor

  • System screw made of electro-galvanized steel with matching polyamide anchor sleeve, which is expanded by screwing the special screw into the plastic anchor
  • Secure fastening for flush-mounted pre-frame installation on the load-bearing masonry with 70 mm edge distance from the drilled hole to the edge of the masonry and a 90 mm contact width of the GU pre-frame to the load-bearing shell

GU assembly screw BE

  • Ensures the proper fastening of the GU front-mounted frame to the supporting shell with a minimum edge distance of 45 mm from the drilled hole to the edge of the wall
  • Easy to install thanks to the variable installation and adhesive width of the front-mounted frame from 65 to 90 mm to the masonry

GU assembly screw BE

  • Ensures the proper fastening of the GU front-mounted frame to the supporting shell with a minimum edge distance of 45 mm from the drilled hole to the edge of the wall
  • Easy to install thanks to the variable installation and adhesive width of the front-mounted frame from 65 to 90 mm to the masonry

GU assembly screw BE

  • Ensures the proper fastening of the GU front-mounted frame to the supporting shell with a minimum edge distance of 45 mm from the drilled hole to the edge of the wall
  • Easy to install thanks to the variable installation and adhesive width of the front-mounted frame from 65 to 90 mm to the masonry

GU 1C assembly adhesive

  • Neutral, permanently elastic 1C adhesive and sealant based on hybrid polymer
  • For airtight connection and fastening of the GU front-mounted frame to the masonry

GU 1C assembly adhesive

  • Neutral, permanently elastic 1C adhesive and sealant based on hybrid polymer
  • For airtight connection and fastening of the GU front-mounted frame to the masonry

GU front-mounted frame

  • Material: rigid particle foam free of CFC made of EPS (expanded polystyrene)
  • Easy to process, low bulk density
  • Very high stability and elasticity
  • The air enclosed in the foam beads ensures excellent thermal properties
System components

Perfection in every component

The tested pre-wall frame system from Gretsch-Unitas combines the system components GU pre-wall frame, GU pre-wall anchor, GU installation screw BE, and GU 1K installation adhesive into an optimal installation frame. This ensures reliable installation and sealing around the wall opening.

GU pre-wall frame

GU pre-wall anchor

GU installation screw BE

GU 1K installation adhesive

Standards and safety requirements

Our tested pre-wall frame system guarantees professional installation and sealing in accordance with the recognized rules of technology – for your safety and the highest quality standards. With a system sound insulation value according to DIN 4109 of up to 46 dB, it provides effective sound insulation and a pleasant indoor climate. Thanks to RC3 certification according to EN 1627-1630, the pre-wall frame also offers reliable protection against burglary attempts. In terms of fire protection, the system is also impressive with approvals according to DIN 4102 (class B1) and EN 13501-1 (class E). In addition, the GU pre-wall frame is suitable for fall-proof fixing according to DIN 18008-4, thus ensuring maximum safety during installation. With our system, you meet all relevant standards for modern, safe, and standard-compliant installation of your façade, window, and door elements.

Pictogram for DIN standard DIN 4109
Pictogram for DIN standard DIN 18008-4
Pictogram according to DIN standard DIN 4102
Pictogram for EN standard EN 13501
Pictogram for EN standard EN 1627-1630
All essential information at a glance

General questions about the GU pre-wall frame

The GU pre-wall frame as a system solution offers an innovative way to securely fasten and seal your façade, window, and door elements. Here you will find answers to the most important questions.

Can the GU pre-wall frame be installed on bituminous building waterproofing or coatings?

Can the GU pre-wall frame be installed projecting into the clear masonry opening?

Is there a specification regarding the minimum lengths of the pre-wall frame sections?

What screw spacings must be maintained between the wall fixing points?

Is the GU pre-wall frame only bonded to the building structure?

Is there an installation instruction on how the installation adhesive is applied to the pre-wall frame?

What is the minimum edge distance for the building fixing screws that must be observed?

What screw-in depth must be observed when fixing window elements with the self-tapping GU installation screws BE1, BE2, or BE4?

gu-kontakt-teaser-allgemein-icon
Contact

We are happy to help you!

Do you have any questions or would you like personal advice?
We are happy to assist you – quickly, competently, and reliably.